PROBLEM |
|
PROBABLE CAUSES |
|
|
|
|
|
Energizer not on or no
voltmeter reading across energizer output terminals when disconnected from
fence. |
|
·
Mainline power outage
·
Blown fuse on input circuit
·
Energizer switched off
·
Dry cell batteries dead, wet
cell batteries discharged
·
Terminals corroded
·
Faulty energizer
|
|
|
|
|
|
Energizer on but low
voltmeter reading across energizer output terminals when disconnected from
fence.
(classic signs of bad
transformer)
|
|
·
Energizer switched to low
setting
·
Weak batteries
·
Terminals corroded
|
|
|
|
|
|
Energizer connected &
operating but no voltmeter reading on fence.
(Dead short on fence)
|
|
·
Ground-return wire
disconnected or broken
·
Feedwire terminals corroded,
disconnected or broken
·
Broken live or ground-return
wire on fence
|
|
|
|
|
|
Low voltmeter readings
at several places on fence. |
|
·
Energizer on low setting
·
Energizer inadequate for
length of fence
·
Weak batteries
·
Terminals corroded
·
Ground system inadequate
·
Soil dried out
|
|
|
|
|
|
No voltmeter reading or
low reading at one location on fence. |
|
·
Broken wire
·
Dead short across wires
·
Broken or disconnected jumper
wire
·
Disconnected or deteriorated
ground rod
|
|
|
|
|
|
Voltmeter reading on
one wire higher than another or no reading from one live wire to
ground-return wire or soil. |
|
·
Broken or disconnected fence
wire
·
Broken or disconnected jumper
wire
·
Broken or disconnected ground
wire
·
Broken or faulty insulator
·
Ground rod deteriorated
|
|
|
|
|
|
Radio, TV or telephone
interference.
(major short on fence)
|
|
·
Ground system inadequate
·
Antenna too close to fence
·
Fence parallel with antenna
wires or telephone wires
|